Pool Heater Gas Line Repair · Flower Mound, TX
Written by Steven Shipler, Texas Licensed Master Plumber (Texas License #45825), MBA
This pool heater gas line in Flower Mound, TX had water sitting inside it, so gas never made it to the heater. We pushed the water out with compressed air, hooked the piping back up at the meter, and got the pool and spa heater running again.
Pool Heater Gas Line in Flower Mound, TX: The Fix
This homeowner’s pool and spa heater quit working. She bought a brand-new heater, and it wouldn’t run either. After that, three different plumbers came out to figure out the gas problem, and nobody could.
When we got there, the gas line to the heater wasn’t leaking. It was blocked. There was water inside the pipe, and gas can’t get past water.
So the repair wasn’t a new heater or new pipe. We blew the water out, put the line back together, and the heater fired up.
New heater and still no gas?
Before you buy more parts, let a Master Plumber check the line.
Call or Text 972-333-5448What We Fixed, Step by Step
Step 1: Make sure the house has gas
First stop was inside. The home had gas, so the meter and the supply coming in were fine. Whatever was wrong was out back.

Step 2: Sort out the other outdoor lines

There were three gas lines outside: grill, outdoor fireplace, pool heater. The fireplace is capped on purpose, so it isn’t supposed to have gas. The grill’s valve is broken and stuck shut, and it needs a new valve. That left the heater line as the real problem.
Step 3: Find what’s blocking the heater line

We put the heater line under pressure and it held, which means no leak. But air wouldn’t go through it from the meter side. From the heater side we could draw back just a little. That pointed to water in the pipe.

A testing tube in the line came out wet. That confirmed it.
Step 4: Blow the water out

We hooked up the compressor and used air pressure to drive the water out of the line. After that, air passed freely from either end.
Step 5: Reconnect and fire the heater

We tied the line back in at the meter and checked the far end. Gas was there. Then we hooked the heater back up, the pilot lit, and the pool and spa heater was running again.
What a Homeowner Should Do First
- Smell gas? Leave first. Get everyone away from the area and call your gas company before anything else.
- Check your other gas appliances. If the stove and water heater work but the pool heater doesn’t, the problem is probably on that one line.
- Don’t keep buying parts. A new heater won’t help if gas isn’t getting to it.
- Know which outdoor lines are capped. A capped line with no gas isn’t a problem. It’s just off.
- Call a licensed plumber. In Texas, gas piping work has to be done by a licensed plumber.
What Does a Pool Heater Gas Line Repair Cost in Flower Mound?
Pricing depends on the job. Call or text 972-333-5448 and we’ll tell you what yours needs.
Why Flash Fix
One call covers plumbing, sewer, electrical and air conditioning. Every plumbing job, gas lines included, is run by a Texas Licensed Master Plumber. When a line passes its test but the appliance still won’t run, we keep testing until we know why.
Related Flash Fix Articles
- Flash Fix in Flower Mound, TX: plumber, sewer, electrical and A/C
- Water heater pilot keeps going out
- Sewer line repair in Allen, TX after foundation work
- Flash Fix in Allen, TX
- Flash Fix: plumbing, sewer, electrical and air conditioning
Serving Flower Mound and Nearby Cities
Flower Mound: this pool heater job was in Flower Mound. If your pool heater, grill or fireplace has no gas, we check that line before anything gets replaced.
Lewisville: we fix gas lines to pool heaters, grills and other outdoor appliances in Lewisville homes too.
Highland Village: if your pool or spa heater won’t light, call us before you replace it.
Flash Fix also serves Allen, McKinney, Plano, Richardson, Frisco, North Dallas and Dallas, across Collin County and Dallas County.
Frequently Asked Questions
Why won’t my new pool heater light?
If gas isn’t reaching it, a new heater won’t light either. On this Flower Mound job, water inside the gas line was blocking the gas.
Can a gas line pass a pressure test and still be the problem?
Yes. A pressure test shows the pipe isn’t leaking. It doesn’t show the pipe is open. This line held pressure and was still blocked by water.
How do you get water out of a gas line?
We used air pressure from a compressor to push it out, then checked that air moved freely through the line in both directions.
Do I have to replace the heater if it gets no gas?
Not until the gas line is checked. This homeowner had already replaced hers, and the new one wouldn’t run until the line was cleared.
My grill isn’t getting gas either. What’s wrong with it?
On this home, the valve at the grill is broken and stuck closed. It needs a new valve before gas can get to the grill.
Why doesn’t my outdoor fireplace have gas?
Some outdoor gas lines are capped on purpose. The fireplace line on this home was capped and isn’t meant to have gas.
Can I work on my own gas line?
In Texas, gas piping work has to be done by a licensed plumber. If you smell gas, leave the area and call your gas company.
How much does a pool heater gas line repair cost in Flower Mound?
Pricing depends on the job. Call or text 972-333-5448 and we’ll tell you what yours needs.
Pool heater, grill or fireplace with no gas in Flower Mound?
We’ll find out why and get it running.
Call or Text 972-333-5448
Steven Shipler is a Texas Licensed Master Plumber (License #45825) with an MBA. He runs Flash Fix, Incorporated in Allen, TX, serving Collin County and Dallas County with plumbing, sewer, electrical and air conditioning service.